规格书
|
描述
PS-1050 digital/analog transmitters provide signal conditioning, amplification, and a corresponding digital or isolated analog output signal for tank/bin/hopper weighing systems. Front panel configuration and calibration streamlines system installation and operation.
Calibration and configuration parameters also can be downloaded via PC based Pro-View Software. In either case, no dip switch or potentiometer adjustments are required.
An isolated 0-10V or 4-20mA analog output provides factory floor communication for a data logger, remote panel meter, or PLC input. High level serial communication is available in RS-232, RS-422, or RS-485 format with Modbus RTU protocol. Up to 32 PS-1050’s can be connected point-to-point using the RS-485 serial output.
Convenient 1/8 DIN size panel mounting and removable terminal block connectors simplify installation procedures.
BLH offers the PS-121, 24Vdc Power Supply (data sheet #12155), for PS-1050 operation.
特征
•Push-button configuration and calibration
•10-Point load cell linearization
•Selectable 0-10Vdc or 4-20mA isolated analog output
•Peak hold functions for dynamic/historic measurement
•Keypad entry or conventional dead load calibration
•Selectable/adjustable digital filtering
•Serial communication and Modbus RTU protocol
应用
•Storage tank, bin, and hopper weighing
•Silo and inventory measurement systems
•Loss-in-weight feeders
•Floor and bench scale indication
|